15 inch Unico Explosion Proof Floor Machine
· Comes with Bassine Scrub Brush
(For use in Class 1 Hazardous Locations!)
Regular Price: $6450.00
Sale Price: $5860.00
Optional Accessories:
· 15" Union Mix Explosion Proof Polishing Brush
· 15" Bassine Explosion Proof Scrubbing Brush
· 15" Beryllium Bronze Explosion Proof Brush
This 15 inch explosion proof floor machine is classified for use in Class 1 Hazardous Locations, as described by the National Electrical Code (NEC). The Unico explosion proof floor machines are tested with respect to the acceptability of operation in the presence of flammable and explosive mixture of specific vapors and gases with air. Equipment classified for use in Class 1 locations is not necessarily acceptable for Class 2 locations as it may not be Dust-Tight or operate at a safe temperature when blanketed with dust. This machine is available in 50 or 60 hertz, and 110 or 220 volts.
Protection against explosions in hazardous locations requires that all electrical equipment exposed to the flammable or combustible atmospheres be of a type suitable for installation in such locations. Equipment should be installed in circuits with overload and short-circuit protection for established ratings.
For explosion proof equipment as defined in the NEC, acceptability of use in hazardous locations will be endangered should openings or other alterations be made in the enclosure. Holding bolts of enclosing cases and threaded parts must be screwed tight. Continued acceptability of installation will depend upon proper maintenance.
Warnings: - Important to read before use!
· Use ONLY static conductive and spark proof accessories that are certified for use in hazardous locations. These machines and accessories are designed to comply with the NEC.
·
All electrical equipment must be installed and used in strict accordance with the NEC.
·
Regular maintenance inspections are a must! The electrical cord must be inspected every time the machine is used. Any cuts or cracks in the insulation on the cord must be replaced before using.
| Specifications: |
|
| Motor: |
1 H.P. motor, U.L. listed (Class 1, Group D), ventilated, ball-bearing for operation on 60 Cycle Phase, 115 / 230 Volt current, suitable for operation in hazardous locations. Brush speed is 175 R.P.M. through gear reduction. |
| Brush: |
Explosion proof brushes have an aluminum block and have bronze wire throughout the fill to make them conductive. Pad holders and non-approved brushes will void the explosion proof capabilities of this machine. All brushes must be approved by the factory. |
| Gear Unit: |
Completely enclosed and sealed planetary type gear reduction unit. Triple planetary gears assure long life and quiet operation. The unit is lubricated at the factory and requires no further attention. |
| Housing: |
Heavy duty, reinforced cast aluminum brush housing is highly polished. |
| Rubber Bumper: |
Extra wide, heavy duty, conductive rubber bumper around the brush housing provides complete protection. |
| Wheels: |
5 inch diameter aluminum conductive wheels with bronze bushings. The entire wheel carriage retracts to permit full weight of the machine on the brush when the machine is in operation. |
| Handle: |
Handle assembly is constructed of U.L. listed explosion proof fittings and welded to prevent from loosening. The handle assembly is a fully adjustable 90 degrees for operator comfort and ease of storage. Two cord hooks provide convenient storage for the trailing cord. |
| Switch: |
Shock proof, double pole, momentary contact switch shuts off when the switch lever is released. |
| Cord: |
50 foot, heavy duty reinforced U.L. listed 14/3 conductor cable. No plug is provided with the cord. |
| Appearance: |
All cast aluminum parts are highly polished and all other exterior metal parts are chrome plated, except the handle fittings, which are aluminum painted. |
Certified for use with Class 1, Group D hazardous materials - Atmospheres such as: acetone, acrylonitrile, ammonia, benzene, butane, 1-butanol, 2-butanol, n-butyl acetate, ethane, ethanol, ethyl acetate, ethylene dichloride, gasoline, heptane, hexane, isoamyl alcohol, isoprene, methane, methanol, methyl ethyl ketone, methyl isobutyl ketone, 2-methyl-1-propanol, naptha, octane, pentane, 1-pentanol, propane, 1-propanol, 2-propanol, propylene, styrene, toluene, vinyl acetate, vinyl chloride, and xylenes. |